Technical Requirements:
1.Standards:The electric heater is designed and manufactured in strict accordance with JB / t2379-93 standard. Explosion proof electric heater is designed and manufactured in strict accordance with gb3836.1 ~ 3-2010 standard.
2.Rated Voltage:415V, 3 Phase, 50Hz.
3.Power:68KW(3 steps). ∅11 U-type heating tubes 9pcs,7.55KW/pc.
4.Heating Media:Air; Designed Temp:110℃; Working Temp:90℃.
5.Designed Pressure:1.2MPa; Working Pressure:1.0MPa
6.Surface Load:2w/cm² .
7.Explosion Proof Grad:ExdIIBT4; Protection Level:IP56.
8.Withstand voltage test:2000V/min, and bear 1.6MPa/30min water pressure test.
9.Insulation resistance greater than50MΩ.
10. Sheath Material: Incoloy800.